Corona pandemic could be better tackled by reducing aerosol transmission

Leipzig, 08.12.2020

Working committee particulate matter (AAF) recommends concrete countermeasures for indoor areas: masks, ventilation, air purification and overhead extraction

 

 

Leipzig/Frankfurt/Main/Düsseldorf. Aerosols and their spread play an essential role in the transmission of COVID-19. However, the risk of transmission could be significantly reduced if more could be done to reduce indoor airborne viruses. The Working committee particulate matter (AAF) has therefore issued an statement with concrete recommendations. These include window ventilation, exhaust ventilation, air purification systems and CO2 measuring devices for indoor areas such as classrooms or transportation, and the increased use of N95 and FFP2 masks. These countermeasures could help in the short term to better contain the corona pandemic, especially in winter, until vaccination is effective on a large scale. They could also help in the long term to better control infections such as seasonal fluor even other pandemics in the future.

 

 

The German Working committee particulate matter (AAF) brings together experts from the fields of engineering, chemistry, physics, biology, meteorology and medicine, who are organised in the professional associations ProcessNet (DECHEMA/ VDI-GVC), Gesellschaft Deutscher Chemiker (GDCh) and VDI/DIN Commission Reinhaltung der Luft (KRdL). In its autumn meeting, the AAF discussed the role of aerosol particles in the spread of the SARS-CoV2 viruses and prepared a statement on this topic. On the basis of their expertise, the authors describe in the now published statement different aerosol types with regard to their formation, range, residence time in the air and derive recommendations for protection by various measures. The authors expressly support the current recommendations of the Robert Koch Institute (RKI), but suggest that even more should be done to reduce the number of viruses in indoor air.

 

The Working committee particulate matter (AAF)  advises strict application of the recommendations based on the active aerosol propagation path: masks (especially the use of N95 and FFP2 masks) are helpful and necessary, ventilation is a good immediate measure and suitable air purifiers should be used.

Furthermore, the Panel concludes that more attention should be paid to the type of ventilation in addition to the measures already taken: Especially the smaller aerosol particles rise with the warm air we breathe and then spread below the ceiling. The experts on the working committee therefore recommend that in ventilation systems, care should be taken to ensure that fresh air is not supplied from top to bottom, as this leads to turbulence between the fresh air and the air we breathe and viruses can then float in the room air for longer. Ceiling fans, which are counterproductive in the current COVID 19 pandemic, would also contribute to this. Instead, care should be taken to ensure that air is actually extracted upwards. In the future, a reversal of the air supply and extraction in aircraft or public transport could help.

 

The panel of experts also advises to install ventilation and especially overhead exhaust suction  systems in many areas at short notice, especially in classrooms or in the catering industry. Monitoring the CO2 concentration is a suitable indicator of how well the ventilation works. For cultural facilities, too, monitoring the CO2 content and thus the indoor air could later provide opportunities for normalising operation. In the Länder, funds should be made available so that ventilation, extraction, air purification systems and CO2 measuring devices can be installed in school classes. At the local level, it would be helpful if administrative regulations were relaxed and school managements were given more freedom of action. If these measures were implemented consistently, about 90 percent of all potentially viral aerosols could be removed from classrooms.

 

"We clearly see the human and technical effort involved in the short and medium term, but we are convinced that the appropriate consideration of the virus spread via the aerosol path can lead to a short-term and also sustainable containment of the current incidence of infection. Such investments would also be beneficial for later, for example for the air quality in classrooms", explains Prof. Hartmut Herrmann of the Leibniz Institute for Tropospheric Research (TROPOS), who is chairman of the Working Committee on Particulate Matter (AAF). Herrmann also contributes torecommendations by an international group of aerosol researchers (https://tinyurl.com/FAQ-aerosols) and via the VDI/DIN Commission on Air Pollution Control (KRdL), which were incorporated into specific recommendations for German conditions. Even if the World Health Organization (WHO) still pays too little attention to this, experts have long been convinced that aerosols, i.e. tiny suspended particles in the air, contribute strongly to the spread of the SARS-CoV2 viruses. "We are aware that the technical implementation of more efficient ventilation measures is probably one of the most demanding measures in the current situation in Germany. However, protection against infection from virus-contaminated aerosol particles in indoor rooms and means of transport through improved ventilation technology is particularly important in the cold winter months in order to avoid corona superspreader events", emphasises Prof. Peter Wiesen from the Bergische Universität Wuppertal, who is one of the authors of the statement.

 

In addition to the recommendations already made by the Robert Koch Institute and the National Academy of Sciences Leopoldina in Germany, the Working Committee sees an opportunity to take additional protective measures to contain the Covid-19 pandemic, initially in the short term, until a vaccine has reached a really broad section of the population. In addition, these measures could in the future also help to reduce infections such as seasonal influenza, which are spread through the air.

 

 

 

Publication:

Covid-19 and the role of aerosol particles - Statement of the Working committee particulate matter  (AAF) of DECHEMA/ProcessNet, GDCh and KRdL

https://www.tropos.de/en/current-issues/press-releases/statements

 

The Working committee particulate matter (AAF) is a body of the following scientific associations: DECHEMA (Gesellschaft für Chemische Technik und Biotechnologie e.V. Frankfurt; ProcessNet: Platform for Chemical Process Engineering of DECHEMA and VDI-GVC (with VDI: Verein Deutscher Ingenieure e.V., Düsseldorf and GVC:Gesellschaft für Verfahrenstechnik und Chemieingenieurwesen im VDI e.V. Düsseldorf; GDCh (Gesellschaft Deutscher Chemiker e.V., Frankfurt) and KRdL (VDI/DIN Commission Reinhaltung der Luft (KRdL) - Standards Committee, Düsseldorf).

This statement is supported and co-sponsored by the Leibniz Institute for Tropospheric Research (TROPOS) and the Gesellschaft für Aerosolforschung (GAeF).

The statement was drafted by H. Herrmann, P. Wiesen, R. Zellner and C. Zetzsch with contributions from E. Hösen-Seul, W. Koch, U. Krämer, G. Lammel, A. Mayer, S. Metzger, S. Nehr, U. Pöschl, E. Schmidt and K. Schwarz.

 

 

 

Media contacts:

 

Prof. Hartmut Herrmann

Head of Working committee particulate matter (AAF)

Head of the Atmospheric Chemistry Department at the Leibniz-Institute for Tropospheric Research (TROPOS), Leipzig
Phone: +49-341-2717- 7024

https://www.tropos.de/institut/ueber-uns/mitarbeitende/hartmut-herrmann

 

and

Tilo Arnhold

TROPOS Public Relations

Phone: +49-341-2717-7189

https://www.tropos.de/en/current-issues/press-releases

 

 

 

Further information:

 

Working Committee particulate matter (AAF)

https://processnet.org/en/Sections/SuPER/Particulate+Matter.html

 

FAQs on Protecting Yourself from COVID-19 Aerosol Transmission

https://tinyurl.com/FAQ-aerosols
KRdL version under

https://www.vdi.de/fileadmin/pages/vdi_de/redakteure/themen/Corona/Dateien/Das_Corona-FAQ_VDI.pdf

 

Support for the appeal of protective measures against the airborne spread of Covid-19

https://www.tropos.de/en/current-issues/press-releases/statements/unterstuetzung-appell-bezuegich-covid-19

 

 

 

 

 

The Leibniz-Institute for Tropospheric Research (TROPOS) is member of the Leibniz Association, which connects 96 independent research institutions that range in focus from the natural, engineering and environmental sciences via economics, spatial and social sciences to the humanities. Leibniz Institutes address issues of social, economic and ecological relevance. They conduct knowledge-driven and applied basic research, maintain scientific infrastructure and provide research-based services.

The Leibniz Association identifies focus areas for knowledge transfer to policy-makers, academia, business and the public. Leibniz institutions collaborate intensively with universities – in the form of “Leibniz ScienceCampi” (thematic partnerships between university and non-university research institutes), for example – as well as with industry and other partners at home and abroad.

They are subject to an independent evaluation procedure that is unparalleled in its transparency. Due to the importance of the institutions for the country as a whole, they are funded jointly by the Federation and the Länder, employing some 20,000 individuals, including 10,000 researchers.

The entire budget of all the institutes is approximately 1.9 billion Euros. They are financed jointly by the Federal Government and the Länder. The basic funding of the Leibniz Institute for Tropospheric Research (TROPOS) is therefore financed by the Federal Ministry of Education and Research (BMBF) and the Saxon State Ministry of Science and the Arts (SMWK). The Institute is co-financed with tax revenues on the basis of the budget approved by the Saxon State Parliament.

https://www.leibniz-gemeinschaft.de/en/home/

https://www.bmbf.de/en/index.html

https://www.smwk.sachsen.de/

 

 

 

Schematic representation of the proportions of SARS-CoV-2 viruses (0,1 µm) in aerosol particle emissions of the nose and the mouth. (From left to right: (A) Basal respiration, (B): Speaking, singing, and shouting (mouth), (C): Even larger droplets are emitted of the nose and the mouth when sneezing. Suspended viruses are embedded in saliva or dried up lung liquid, cold and damp climate and darkness extend their activity. The particles A can hover longer than one day in unventilated rooms, the particles B several hours. The largest particles (C and mostly bigger) of the sneezing sink to the ground within few seconds. In contrast to cloth face masks N95 and FFP2 masks protect as well against the particles A.)
Visualization: Hartmut Herrmann / Konstanze Kunze, TROPOS